221. TSD108 | Contact Microphone | BIOPAC - Research
|
|
to the DA100C:
Black = Ground (GND)
Blue = Positive and Negative, interchangeable (Vin+ and Vin-)
When using this transducer with the EBI100C module, do not connect the GROUND pin of the TSD108 to the DA100C module. Doing so will cause inaccurate impedance measures, because the TSD108 contact surface is tied to isolated ground. An alternative is to insulate the TSD108 from the skin surface by using a latex balloon or some other non-conductive barrier. If this latter procedure is followed, the GROUND pin may be attached to the DA100C module.
See also : Telemetry System equivalent— SS17 and
|
|
|
|
222. LEAD130 | NICO100C/EBI100C Lead | BIOPAC - Research
|
|
Red = Vin+ Green = Vin- Black = I- (GND)
IMPORTANT USAGE NOTES:
If using multiple biopotential modules, do not connect the ground (GND) for the other modules -- establish one ground per subject.
If using a GSR100C Electrodermal Response Amplifier with the EBI100C or the NICO100C, please note that the I- connection will shunt current from the GSR100C current source. Accordingly, GSR100C measurement values will be shifted somewhat high in absolute conductance, and should be used as relative measures only.
See the new EL506 Bioimpedance Strip electrode, or other disposable electrodes in the EL500 Series .
|
|
|
|
223. RX202A | Sensor for SS6/6L+TSD202A (repl.) | BIOPAC - Research
|
|
with transducer connector (black); ships as sensor only .
This is a replacement sensor for
TSD202A for MP research systems
SS6L for BSL education systems
SS6 for telemetry/wireless systems
The sensor snaps onto the "SS" transducer connector for connection to a BIOPAC data aquisition system.
You might also be interested in the following items:
Item
Description
|
|
|
|
224. TSD142 | LDF Digit Surf Probe | BIOPAC - Research
|
|
surface probes are made from black Delrin. The signal delivery fiber intersects the probe body at a right angle, making the probes easy to secure to the skin or tissue surface. Surface probes are non-suturable, unless otherwise indicated. All surface probes are MRI compatible (as defined by BIOPAC ), autoclavable, and come with a 3-meter cable for connection to the LDF100C module.
This probe was specially developed for measuring microvascular skin blood flow in the digits; the curved geometry of these probes makes them ideal for studying conditions such as Raynaud's disease.
|
|
|
|
225. TSD140 | Laser Doppler Std Surf Probe | BIOPAC - Research
|
|
surface probes are made from black Delrin. The signal delivery fiber intersects the probe body at a right angle, making the probes easy to secure to the skin or tissue surface. Surface probes are non-suturable, unless otherwise indicated. All surface probes are autoclavable have a 3-meter cable for connection to the LDF100C module.
This robust and easy to handle probe is ideal for taking measurements of cutaneous blood flow anywhere on the skin surface.
See also : BIOPAC MRI Guidelines .
You might also
|
|
|
|
226. EL160 | Au cup electrode, blk, reuse | BIOPAC - Research
|
|
10 mm cup diameter and 1.2 m black cable. One electrode per package.
Also available: EL160-R with red cable and EL160-W with white cable.
The leadwire terminates in a standard Touchproof connector. Use with MEC Series Module Extension Cables for MP Research Systems or SS1LA Touchproof Electrode Lead Adapter for BSL Systems.
You might also be interested in the following items:
Item
Description
|
|
|
|
227. EYETRAKHMD1MONO | Eye Tracking System with HMD1, Monocular | BIOPAC - Re...
|
|
of view scene camera or a black and white 60º horizontal field of view scene camer
Analog output (4 channels)—real-time analog voltage signals
4-Channel 12-Bit Analog Output Board with 48-Bits of Digital I/O
AnalogOut software for use with ViewPoint PC-6
2' 100 Pin High Density Connector to 2 50 Pin IDC
50 Pin Universal Screw Terminal and screws
TTL capabilities
Interface cables to MP System: CBL102 x 2 and
|
|
|
|
228. EYEFRAMESCENEMO | Eye Tracking Scene Camera, mounted, Monocular | BI...
|
|
of view scene camera or a black and white 60º horizontal field of view scene camera
Universal power supply with country specific adaptor and 10M video and power cable.
Waist pack cable holder (not shown)
Analog output (4 channels)—real-time analog voltage signals
4-Channel 12-Bit Analog Output Board with 48-Bits of Digital I/O
AnalogOut software for use with ViewPoint PC-6
2' 100 Pin High Density Connector to 2 50 Pin IDC
50 Pin Universal Screw Terminal and screws
TTL
|
|
|
|
229. EYEFRAMESCENEBI | Eye Tracking Scene Camera, mounted, binocular | BI...
|
|
of view scene camera or a black and white 60º horizontal field of view scene camera
Universal power supply with country specific adaptor and 10 M video and power cable.
Waist pack cable holder (not shown)
Analog output (4 channels)—real-time analog voltage signals
4-Channel 12-Bit Analog Output Board with 48-Bits of Digital I/O
AnalogOut software for use with ViewPoint PC-6
2' 100 Pin High Density Connector to 2 50 Pin IDC
50 Pin Universal Screw Terminal and screws
TTL
|
|
|
|
230. ACK100W | AcqKnowledge Software - Win | BIOPAC - Research
|
|
print waveform data in black
A daptive scaling—vertical scale updates in real time to optimize data display
Grids—Friendly grid scaling; Flexible grid options Grid Tool
Balloon Help
Multiple levels of Undo
Jump tool
Rescale operations
Selection palette—place cursors at specific time points
Mouse scrollwheel support
Keyboard Shortcuts added (accelerator keys)
|
|
|
Result page:
Previous
Next
|